VISTA™ Industrial Fold Down Ladder - 3200mm
-
The VISTA KATTSAFE commercial fold down ladder provides ultimate user safety with a pneumatic soft close design for access to ceiling spaces and areas requiring maintenance to plant and equipment.
The adjustable, easy to install fold down ladder suspension kit attaches to the roof support structure which provides structural and lateral stability to the ladder system. Support flanges around the ladder frame provide an easy and neat finish to suspended or solid ceiling systems.
-
150kg rated
-
Built to suit any roof type including standard, timber truss and lightweight suspension ceilings
-
Adjustable feet
-
Large height range
Materials -
-
All components and accessories manufactured from high grade structural aluminium with options for powder coating.
- Dimensions
-
LD461
-
Standard or suspended ceiling type
-
Floor to ceiling height: 2200mm to 3200mm
-
Ceiling opening required: 1230mm x 785mm
LD463
-
Standard or suspended ceiling type
-
Floor to ceiling height: 2200mm to 4300mm
-
Ceiling opening required: 1630mm x 785mm
-
- Weight
-
-
LD461: 40kg
-
LD463: 50kg
-
- Fixings
-
-
Metal fixing: M8 bolt set into support structure
-
Concrete fixing: M10 mechanical concrete anchor
-
Metal purlin fixing: M8 bolt
-
- Substructure requirements
-
Support structure integrity, suitability and fixing method to be assessed and determined by a competent person prior to installation.
- Rating
-
-
Recommended for single person use - 150kg rated
-
Industrial rated, suited to high frequency usage
-
- Compliance
-
-
Kattsafe VISTA fold down ladders are designed to comply with requirements of Australian Standard AS1657:2018 and relevant statutory OHS Codes of Practice/Guidelines.
-
Fold down ladders are not specifically detailed in the AS1657:2018 Standard.
-
- Testing
-
Testing and performance based on requirements for fixed rung ladders of Australian Standard AS 1657:2018.
- Product Warranty
-
3 years from the date of purchase subject to correct installation. Use and maintenance to be in accordance with manufacturer's specifications and recommendations.
- Inspection & maintenance
-
Inspection and certification required every 12 months by competent person in accordance with manufacturer’s specifications and requirements of Australian Standards AS/ NZS 1891 and AS/NZS 5532. (Refer to installation manual).
- Important notes
-
Failure to supply and/or install proprietary product in accordance with above standards and codes, specifications and instructions voids complete system certificate and/or warranty.