Raptor™ Davit Arm, 1000mm (L) 2500mm (H)
Unit weights
-
Boom: 15kg
-
Brace: 9kg
Specifications
- Materials
-
-
Arm and mast: manufactured from high grade structural aluminium
-
Connection brackets, end caps, supports: powder coated stainless steel
-
Davit base: G350 grade steel, galvanised finish
-
- Fixings (refer to installation manual)
-
Epoxy Adhesive
-
Stainless or HDG M16 x 180mm allthread stud fixing for 1000mm reach OH510 davit range, min 120mm embedment. Requires 18mm hole size.
-
Stainless M16 x 200mm allthread stud fixing for 1400mm reach OH514 davit range, min 140mm embedment - requires 18mm hole size
-
Recommended epoxy adhesive: SD944E (EF500R+)
-
- Cast-in
-
AP160 cage bolt kit or OH522 flush mount base
-
Minimum concrete thickness: AP160: 220mm, OH522: 300mm
-
Minimum concrete strength: 32Mpa
-
- Weight
-
-
OH510.1600: 41kg total weight (excluding base)
-
OH510.2200: 48kg total weight (excluding base
-
- Substructure requirements
-
-
Minimum concrete thickness:
-
OH510 epoxy adhesive fix: 200mm
-
OH514 epoxy adhesive fix: 220mm
-
AP160 cast-in cage bolt kit: 220mm
-
OH522 flush mount cast-in base: 300mm
-
Minimum concrete strength: minimum 32 mPa
-
Concrete may need to be verified by engineer regarding reaction loads
-
Minimum 250mm edge distance
-
- Rating
-
-
12kN single person use + rescue
-
400kg safe working load
-
- Compliance
-
Kattsafe davits are designed to conform to requirements of Australian & New Zealand Standards AS/NZS 5532:2013, AS/NZS ISO 22846, AS/NZS 1891 and relevant statutory codes of practice and guidelines
- Testing
-
Testing and performance based on requirements of Australian & New Zealand Standards AS/NZS 1891 and AS/NZS 5532.
-
Dynamic load test: 15kN
-
Static load test: 12kN
-
- Product Warranty
-
10 years from the date of purchase subject to correct installation. Use and maintenance to be in accordance with manufacturer's specifications and recommendations. (This excludes wearing parts).
- Inspection & maintenance
-
Inspection and certification required every 12 months by competent person in accordance with manufacturer’s specifications and requirements of Australian Standards AS/NZS 1891 and AS/NZS 5532 (refer installation manual).
- Important notes
-
Failure to supply and/or install the proprietary product in accordance with above standards and codes, specifications and instructions voids complete system certificate and/or warranty.